The M3036 conductivity meter is suitable for water, waste water or pure water conditioning in continuous or batch-type operating modes, for liquid chromatography or for general chemical process monitoring.
- Conductivity meter for 0 … 20/200/2000/20000/200000uS
- USB data logger
- Galvanically separated sensor cirquit
- Galvanically separated signal output. free configurable between 0 and 20mA.
- Precision 3-wire PT100 temperature input
- Up to 5 limit contacts
- Universal power supply: All voltages between 20VAC/DC and 253VAC/DC possible
Specifications
Measuring ranges: | 0…2.000µS C = 0.01, C = 0.1
0…20.00µS C = 10.0, C = 1.0, C = 0.1, C = 0.01 0…200.00µS C = 10.0, C = 1.00, C = 0.1 0…2.000mS C = 10.0, C = 1.00, C = 0.1 0…20.00mS C = 10.00, C= 1.0 0…200.0mS C = 10.0 |
Accuracy: | 0.50% |
Display: | Graphic LCD 128×128 pixel |
Pixel size: | 0.4×0.4mm |
Temperature drift: | Max. 50µV/°C |
Max. humidity: | 95%, non condensing |
Temperature compensation: | Manual from 0 to 130°C.
Automatic with external Pt-100, 3-wire sensor. Wire break of the Pt 100 sensor switches the device to 25°C. Manual / automatic with (F4) |
Temperature slope: | 0.00%/°C (no compensation) to 8.00%/°C |
Self conductivity of water: | controlled and compensated to 25°C |
Reference temperature | 25°C |
Max. length of cell cable: | Cable capacity is compensated until max capacity of 10nF or (10-8F) |
ENT key: | Quick access to settings or to save parameters |
ESC key: | Access to the main menu, press and hold for 3 seconds, or exit menu item |
+ / – key: | Set values |
F3 key: | Change measuring range of measuring value, limit contacts and alarm limits |
Programming functions: | Company label and various setting options via software |
Signal current output:
– Max load: – Output impedance: |
0…20mA programmable, isolated against electronic ground
<500Ω Typ. >1MΩ |
Relay contacts: | Adjustable over the full range |
Hysteresis: | 5 – 200 digits adjustable |
Limit value status | Displayed with green LEDs for contact 1/2, no LEDs for optional contact 3/4 |
Relay outputs: | Floating changeover contacts, max. 6A, 2A at 230VAC continuous inductive load |
Alarm functions: | 2 programmable limits, Pt-100 alarm if wires are broken, ‘1Wire’ alarm if wires are broken, alarm if the pump’s max. run time times out and an USB alarm if the stick/media is full. The alarm is displayed with the red LED and on display. Alarm can be acknowledged. |