Product
Conductivity meter with USB logger type M3036
					Minh Quan Technology Joint Stock Company
Hotline: 01692 114 683
Mr Que: 0973 852 363
Ms Ha: 0165 2197 433
Email: mqtekvietnam@gmail.com
Call usProduct information
The M3036 conductivity meter is suitable for water, waste water or pure water conditioning in continuous or batch-type operating modes, for liquid chromatography or for general chemical process monitoring.
- Conductivity meter for 0 … 20/200/2000/20000/200000uS
 - USB data logger
 - Galvanically separated sensor cirquit
 - Galvanically separated signal output. free configurable between 0 and 20mA.
 - Precision 3-wire PT100 temperature input
 - Up to 5 limit contacts
 - Universal power supply: All voltages between 20VAC/DC and 253VAC/DC possible
 
Specifications
| Measuring ranges: | 0…2.000µS C = 0.01, C = 0.1
 0…20.00µS C = 10.0, C = 1.0, C = 0.1, C = 0.01 0…200.00µS C = 10.0, C = 1.00, C = 0.1 0…2.000mS C = 10.0, C = 1.00, C = 0.1 0…20.00mS C = 10.00, C= 1.0 0…200.0mS C = 10.0  | 
| Accuracy: | 0.50% | 
| Display: | Graphic LCD 128×128 pixel | 
| Pixel size: | 0.4×0.4mm | 
| Temperature drift: | Max. 50µV/°C | 
| Max. humidity: | 95%, non condensing | 
| Temperature compensation: | Manual from 0 to 130°C.
 Automatic with external Pt-100, 3-wire sensor. Wire break of the Pt 100 sensor switches the device to 25°C. Manual / automatic with (F4)  | 
| Temperature slope: | 0.00%/°C (no compensation) to 8.00%/°C | 
| Self conductivity of water: | controlled and compensated to 25°C | 
| Reference temperature | 25°C | 
| Max. length of cell cable: | Cable capacity is compensated until max capacity of 10nF or (10-8F) | 
| ENT key: | Quick access to settings or to save parameters | 
| ESC key: | Access to the main menu, press and hold for 3 seconds, or exit menu item | 
| + / – key: | Set values | 
| F3 key: | Change measuring range of measuring value, limit contacts and alarm limits | 
| Programming functions: | Company label and various setting options via software | 
| Signal current output:
 – Max load: – Output impedance:  | 
0…20mA programmable, isolated against electronic ground
 <500Ω Typ. >1MΩ  | 
| Relay contacts: | Adjustable over the full range | 
| Hysteresis: | 5 – 200 digits adjustable | 
| Limit value status | Displayed with green LEDs for contact 1/2, no LEDs for optional contact 3/4 | 
| Relay outputs: | Floating changeover contacts, max. 6A, 2A at 230VAC continuous inductive load | 
| Alarm functions: | 2 programmable limits, Pt-100 alarm if wires are broken, ‘1Wire’ alarm if wires are broken, alarm if the pump’s max. run time times out and an USB alarm if the stick/media is full. The alarm is displayed with the red LED and on display. Alarm can be acknowledged. | 