Temperature
Isolating amplifier without supply type M2931
Minh Quan Technology Joint Stock Company
Hotline: 01692 114 683
Mr Que: 0973 852 363
Ms Ha: 0165 2197 433
Email: mqtekvietnam@gmail.com
Call usProduct information
- passive isolating 1:1
- up to 4 separate isolating amplifiers
- range 0…27mA
- 17.5mm small case
Product Details
This “snap-on” interface module utilize isolating amplifier channels to galvanically isolate DC current signals without a power supply.
The input current signal can be in the range of 0…27mA. This DC signal is converted to an AC signal, transformed 1:1 to the secondary, rectified and ripple rejected by a filter, thus restoring the original DC current signal.
The small 17.5mm case contains up to 4 separate isolating amplifiers.
The output can be on a common mode voltage or on different ground and may feed remote displays, recorders, PLC’s analog input, computers and data loggers.Applications:
Heating, air conditioning, signal isolation, data logging applications etc.
Specifications
Input | |
Input current (IE ): | 0…5mA, 0…20mA, 4…20mA, max. 27mA |
Max. input current: | 50mA with open output |
Max. input voltage (U ); | +20V |
Max. voltage drop: | 3,7V |
Output | |
Current transfer ratio (I : I ): | 1,0 : 1,0 |
Max. load: | ≤500Ω |
Load error: | Typ. ±0,1% |
Output ripple | 0,9% (R =280W, I =20mA, f=3,5kHz) |
Rise time: | Typ. 75ms |
Working temperature range: | -10…+60°C (max± 0,1%/20mA) |
Coupling | |
Internal oscillator: | Typ. 3,5 kHz |
Max. common mode voltage (Umax ): | 230VAC RMS, Testvoltage: 2500Veff /1’. |
Operating Principle | The input signal is chopped with 3.5kHz, transformed from the primary to the secondary by a transformer, rectified and filtered. (see block diagram) |
Supply current: | None, will be drawn out of the primary signal |
CE-Conformity: | fulfilled |
Weight: | Xấp xỉ 130g |
Warranty: | 2 years |
Reviews
Related Products
Load cell type M2428-14
Code: Product Details The M2428-14 is a low-cost load cell to measure weights or forces in the range of 25kg (~250N) to 30'000kg (~300'000N). The bending beam consists of a strain gage sensor with integrated electronics to convert the force or weight to a 4…20mA signal. There is no need to use external, sensitive strain gage amplifiers or signal conditioning devices. A cell connects directly to any 2-wire sensor input of process control computers or other control equipment and displays. The bending beam confirms the protected class IP67 an delivered with open cable ends. Any range within the measuring range can be programmed. E.g. 45kg to 420kg = 4 to 20mA within a calibrated range of 0 to 500kg.