Temperature
Temperature transmitter type TLC/22GW
Minh Quan Technology Joint Stock Company
Hotline: 01692 114 683
Mr Que: 0973 852 363
Ms Ha: 0165 2197 433
Email: mqtekvietnam@gmail.com
Call usProduct information
Specifications
Sensors: | Platinum or nickel with 100, 200, 500 or 1000 at 0°C (DIN 43760) in 2- or 3-wire circuit |
Signal output: | 0…20mA, 4…20mA, 0…1V, 0…10V in a range of -100…+500°C for platinum, resp. – 40…+180°C for nickel |
Accuracy at 23°C ambient: | ±0.1% in a the range of -50…+300°C for platinum, -40…+180°C for nickel |
Reproducibility: | Better than 0.1% |
Temperature coefficient | Zero drift typ. 20ppM/°C, gain drift typ. 15ppM/°C |
Long-term stability: | ±0.15% after 3 months |
Working temperature range: | -5 to 45°C |
Max. humidity: | 95%, non-condensing |
Max. length of sensor cable: | 3-wire shielded, up to 20W cable resistor, symertically (»300m)
2-wire shielded, error depends on cable resistance |
Max. length of output signal cable: | 2000m, 2-wire shielded |
Max. current signal loading: | ≤700 Ω |
Output current signal impedance: | 1MΩ |
Zero / gain adjustment: | The zero and gain can be adjusted by potentiometers. |
Terminals: | Screw terminals,12-pole |
Mounting | 35mm mounting rail, EN50022-35 |
Weight: | Xấp xỉ 130g |
CE-conformity: | fulfilled |
Power supply: | 20 to 253VAC or DC |
Power supply load: | 2.0W |
Limit contact (optional):
Adjustable Hysteresis: Contact rating: Contact debouncing (optional): |
In the range 0…+255ºC , set at the side panel, others on request
0.5…5°C, adjustable at the side panel 1A/250V resistive, norm. open/closed contact RC-filter (0.033mF/100W) on the norm. open contact |
Warranty | 2 years |
Reviews
Related Products
Load cell type M2428-14
Code: Product Details The M2428-14 is a low-cost load cell to measure weights or forces in the range of 25kg (~250N) to 30'000kg (~300'000N). The bending beam consists of a strain gage sensor with integrated electronics to convert the force or weight to a 4…20mA signal. There is no need to use external, sensitive strain gage amplifiers or signal conditioning devices. A cell connects directly to any 2-wire sensor input of process control computers or other control equipment and displays. The bending beam confirms the protected class IP67 an delivered with open cable ends. Any range within the measuring range can be programmed. E.g. 45kg to 420kg = 4 to 20mA within a calibrated range of 0 to 500kg.