Relay Test Equipment
1200A-3PH Current Injection
Minh Quan Technology Joint Stock Company
Hotline: 01692 114 683
Mr Que: 0973 852 363
Ms Ha: 0165 2197 433
Email: mqtekvietnam@gmail.com
Call usProduct information
Features:
- 0-1200A 3 Phase output.
- Accurate true RMS digital metering.
- All outputs fully isolated.
- Multi-function 1ms resolution timing system.
- Auxiliary AC output.
- Thermal and over-current protection.
- Maximum power output 13kVA
- The 1200A-3PH is a three phase injection system providing commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate.
Each loading unit has two output taps to allow for a range of load impedance. Each phase is isolated and can be configured to either give a maximum of 1200A at 3.5V or 600A at 7V. Three true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output.
An auxiliary metering input is provided and can measure voltage, current, frequency, and the phase between any of the current outputs and an external voltage or current.
The timing system is very flexible without compromising ease of use, allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. Two independently isolated contact inputs are provided, and the timing system may also be used as a stand-alone timer.
The 1200A-3PH can be use to test many single and three phase devices including:
- Over and under current relays
- IDMT relays
- Auto-reclosers
- Time delay relays
- Earth fault relays
- Miniature circuit breakers
- Power relays
- Tripping relays
- Thermal relays
Main Output
The units have three independently controlled outputs, one for each phase. The output is switched on and off by illuminated pushbuttons, and the current is set using the three control knobs on the front panel. All ranges are continuously variable from zero.
Range Continuous 5 minutes 1 minute 20s 3.5V 350A 600A 1000A 1200A 7.0V 175V 300A 500A 600A The above intermittent on-times must be followed by an off-time of 15 minutes, and are based on an ambient temperature of 25°C.
Digital Metering
The output on the 1200A-3PH is metered by a digital true RMS system with a memory ammeter. The currents for each phase are displayed simultaneously.
Range Resolution Trip current Accuracy 60.00A 0.01A 63A ±0.6% rdg+5d 500.0A 0.1A 525A ±0.6% rdg+5d 1200A 1A 1260A ±0.6% rdg+5d An electronic current trip is automatically set to 105% of full scale of the selected metering range to protect the device under test.
The unit is must be supplied by a 400V±10% 50/60Hz 3 phase 1300VA Max.
Timing System
The timing system on the 1200A-3PH is very flexible, allowing a wide range of protective devices to be timed.
Range 0-999.999s Resolution 1ms Accuracy 0.01% rdg +2d (all except current operated mode) 0.01% rdg +4d (current operated mode) The contact circuit has an open circuit voltage of 24Vdc and a short circuit current of 20mA. The contacts may be connected to volt-free contacts or contacts connected to a DC voltage system (240Vdc maximum).
The following functions are provided:
Mode Timer Start Timer Stop Internal Start Press ‘ON’ Contact 1 Single Contact Contact 1 Contact 1 Dual contact Contact 1 Contact 2 Current operated Current > 10% of range Current < 10% of range The output is automatically switched off at the end of the test to safeguard the relay under test.
Protection and Safety
The 1200A-3PH is protected by electronic over current trips on the outputs, fuses on the contact input, the mains input and regulators. An earth terminal is provided for connection to a local earth.
The unit is designed to comply with BSEN61010, and is CE marked.
Reviews
Related Products
Load cell type M2428-14
Code: Product Details The M2428-14 is a low-cost load cell to measure weights or forces in the range of 25kg (~250N) to 30'000kg (~300'000N). The bending beam consists of a strain gage sensor with integrated electronics to convert the force or weight to a 4…20mA signal. There is no need to use external, sensitive strain gage amplifiers or signal conditioning devices. A cell connects directly to any 2-wire sensor input of process control computers or other control equipment and displays. The bending beam confirms the protected class IP67 an delivered with open cable ends. Any range within the measuring range can be programmed. E.g. 45kg to 420kg = 4 to 20mA within a calibrated range of 0 to 500kg.