Features
- 3-φ Voltage output from 1-φ supply
- 0-133V φ-N output voltage, or 0-292V φ-N with optional VT box
- 45VA/phase maximum output
- Variable Frequency 40-999.9Hz
- Phase shift ±180.0°
- Multi-function timing system
- Ideally suited to all testing G59 schemes
- Step change of phase and df/dt
- Large back-lit liquid crystal display
- Compact and lightweight
- Automatic mains voltage selection
- The DVS3 mk2 is the new smaller, lighter, higher power version of the T&R DVS3, offering more than twice the output power of the original DVS3. The exceptionally easy to understand user interface of the DVS3 is retained, allowing simple testing of complex voltage and loss of mains protection systems.Equally at home in a commissioning, maintenance, or laboratory environment, the DVS3 mk2 is a truly flexible system. The DVS3 MK2 has been designed using the latest digital technology to generate a highly stable and accurate output with very low distortion. Each phase output is individually adjustable for voltage and phase angle. In addition, full control of frequency is available. Step changes of any quantity may be generated with automatic timing of the response of the relay under test.The unit is controlled by a simple user interface with context sensitive menus. Values may be either typed in at the keypad or smoothly varied using a digital potentiometer.The display on the DVS3 is back-lit and exceptionally clear. Menu options on the left are selected by dedicated buttons on the panel next to the display, allowing immediate access to adjust voltage, phase and frequency. Phase to phase and phase to neutral voltages are both shown on the display, along with frequency and phase information. A graphical vector diagram is shown, as is the state of the two contact inputs.
The DVS3 mk2 is ideally suited to testing G59 protection, including loss of mains protection. Vector surge and df/dt (ROCOF) relays may be simply tested and timed, as can other protection requiring one to three voltages, including:
- Under and over frequency relays
- Under and over voltage relays
- Synchronising relays
- df/dt & ROCOF relays
- Vector surge relays
- Transducers
In conjunction with a current source (such as the 200ADM or 50A-3PH), the DVS3 mk2 can be used to test protection requiring current injection with a phase-shiftable voltage including:
- Directional relays
- Distance protection
- Phase angle relays
- Power relays
- Power transducers
DVS3 mk2 Modes of Operation
Variable Frequency Mode
This mode allows full control of frequency, voltage and phase. The voltage and phase may be controlled individually for each phase or for all three phases together. All parameters are continuously variable using the adjust control, and step changes of any value may be generated by typing the required value on the keypad. The new value is applied to the output when the enter key is pressed. The timer automatically resets and starts when a step change of value is entered, and stops if either contact input changes state. Step changes of phase for testing Vector Surge relays are easily generated in this mode.
Frequency resolution | 0.01Hz | 40.00-99.99Hz |
0.1Hz | 100.0-999.9Hz | |
Frequency accuracy | ±0.01%rdg+1d | |
Phase resolution | 0.1º | |
Phase accuracy | ±0.3º phase to phase |
Phase Lock Mode
The frequency and phase of the output are controlled by an external reference in phase lock mode. The reference may be the mains supply to the DVS3 MK2, an external voltage, or an external current. This mode allows testing of directional and distance protection in conjunction with an external current source.
Phase lock range | 45-65Hz |
External voltage ref. | 20-250V AC |
External current ref. | 0.2-5A AC |
Phase resolution | 0.1º |
Phase accuracy | ±0.3º phase to phase |
±3.0º reference to output |
df/dt and ROCOF (Rate Of Change Of Frequency)
Loss of mains protection often takes the form of a df/dt relay, sensitive to the rate of change of frequency over time. The DVS3 MK2 is able to generate a swept frequency output with accurate rates of change of frequency between preset frequencies. The rate of change may be continuously varied to find the relay setting or stepped to time the relay. The output may be set to either sweep continuously or generate single sweeps with timing.
Frequency range | 45.00-65.00Hz |
Default sweep range | 49.75-50.25Hz (50Hz supply) |
59.75-60.25Hz (60Hz supply) | |
Rate of change range | 0.010-2.000Hz/s |
Pre-fault – Fault – Post-fault Mode
PF-F-PF mode allows extra flexibility in testing where complex events must be timed or several sets of values must be applied to a relay in turn. This mode allows three sets of values to be set in advance (pre-fault, fault, and post-fault values). The DVS3 MK2 may be set to switch from one state to the next on a change of contact or after a specific time. In addition, the timer may be set to start or stop on any one of the state changes of a change of contact state. This mode allows frequency, phase and voltage to be changed simultaneously if required.
Reviews
Related Products
Load cell type M2428-14
Code: Product Details The M2428-14 is a low-cost load cell to measure weights or forces in the range of 25kg (~250N) to 30'000kg (~300'000N). The bending beam consists of a strain gage sensor with integrated electronics to convert the force or weight to a 4…20mA signal. There is no need to use external, sensitive strain gage amplifiers or signal conditioning devices. A cell connects directly to any 2-wire sensor input of process control computers or other control equipment and displays. The bending beam confirms the protected class IP67 an delivered with open cable ends. Any range within the measuring range can be programmed. E.g. 45kg to 420kg = 4 to 20mA within a calibrated range of 0 to 500kg.